TB/T is the designation prefix of the Chinese railway industry standards, and the overhead contact system (OCS) is governed by a family of them: one umbrella technical standard, component standards for conductors, fittings, insulators and sectioning devices, and a monitoring specification for operation. A 2026 announcement batch replaced four core documents, led by TB/T 2809-2026 for copper alloy contact wire, with the previous TB/T 2809-2017 withdrawn on 1 September 2026, so old and new dovetail cleanly.

Key Takeaways
- TB/T 2809-2026 governs copper alloy contact wires for electrified railway overhead contact systems and supersedes TB/T 2809-2017, whose withdrawal date of 1 September 2026 is recorded on the National Standards Information Public Service Platform.
- TB/T 3111.1-2026 and TB/T 3111.2-2026 split the strand standard into copper and copper alloy strands and aluminium-clad steel core aluminium stranded conductors; the series first appeared in 2005 and the 2026 round is its second revision.
- The fittings family TB/T 2075 is organized in numbered parts; the 2024 editions include Part 5 terminal anchor clamps, Part 6 mid-point anchors, Part 12 pulley compensation, Part 13 ratchet compensation and Part 14 spring compensation devices.
- Sectioning devices divide by system: TB/T 3036-2016 for 25 kV AC section insulators, the TB/T 3037 series for phase separation and TB/T 3252-2022 for DC 1500 V urban rail.
- TB/T 2073-2020 sets the umbrella technical conditions for OCS components, and TB/T 2076-2020 specifies the 6C operation, inspection and monitoring system.
- National GB/T standards sit alongside the railway layer: GB/T 12971.1-2023 for contact wire, GB/T 1985-2023 for disconnectors, GB/T 11032-2020 for arresters.
How is the TB/T standards system organized for the OCS?
Three layers organize the map. At the top sit umbrella documents that state general technical conditions for whole component classes, TB/T 2073-2020 being the one for OCS components. Below them sit the component families, each with its own TB/T standard or part series. To the side sits the national GB/T layer, which carries the generic versions of products that also exist outside railways.
The table is the map. Read it by component family, and note how often a family has both a TB/T designation and a GB/T companion; that pairing is explained later in this article.
| Component family | Governing TB/T standard | Companion national standard | What the standard covers |
|---|---|---|---|
| Contact wire | TB/T 2809-2026 | GB/T 12971.1-2023 | copper alloy contact wires for electrified railway OCS |
| Stranded conductors | TB/T 3111.1-2026 and TB/T 3111.2-2026 | GB/T 1179-2017 | copper and copper alloy strands; aluminium-clad steel core aluminium stranded conductors |
| Fittings | TB/T 2075 series, 2024 part editions | none as a family | clamps, compensation devices, cantilevers, stitch wires, tunnel supports |
| Section insulators | TB/T 3036-2016 | none | 25 kV AC mainline section insulators, FYFH series |
| Phase separation devices | TB/T 3037 series, TB/T 3037-2002 | none | neutral section insulators, XFXP series |
| Urban rail sectioning | TB/T 3252-2022 | none | rigid suspension catenary busbar and components for DC 1500 V systems |
| Insulators | TB/T 3199.1-2018 and TB/T 3199.2-2018 | none | insulators for electrified railway overhead contact systems |
| Disconnectors | TB/T 2803-2003 | GB/T 1985-2023 | technical conditions for OCS electric disconnectors and control devices |
| Circuit breakers | traction technical conditions | GB/T 1984-2024 with GB/T 11022-2020 | high-voltage AC breaker verification with common requirements |
| Arresters | traction technical conditions | GB/T 11032-2020 | metal-oxide surge arresters for traction duty |
| Supports and masts | TB/T 2286-2020 | GB/T 34199-2017 and GB/T 25020.1-2025 | load class testing for supports; hot-rolled sections and mast product requirements |
| Monitoring | TB/T 2076-2020 | none | 6C operation, inspection and monitoring of high-speed OCS |
Source: TB/T and GB/T designations and scopes as cited in the published OCS corpus and the National Standards Information Public Service Platform catalogue.
What changed in the 2026 conductor standards round?
The 2026 announcement included four standards that relate directly to the overhead contact system: TB/T 2809-2026 for copper alloy contact wires, TB/T 3111.1-2026 for copper and copper alloy strands, TB/T 3111.2-2026 for aluminium-clad steel core aluminium stranded conductors, and the re-issued TB/T 2075 part for preformed fittings. The old documents they replace, including TB/T 2809-2017 and TB/T 3111-2017, were withdrawn in the same round, and in this round the strand scope of the legacy TB/T 2937-1998 was superseded by the TB/T 3111 series.
Each family carries its own lineage. TB/T 2809 has the most complicated history of the group. TB/T 3111 is much newer, first published in 2005, first revised in 2017 and split into two parts in the 2026 second revision. The preformed fittings part of TB/T 2075 is the youngest of the set: issued on 30 October 2020, effective 1 May 2021, reviewed 12 September 2024 and re-issued in 2026 immediately after that review. The full story of this revision round is told in our deep dive on the four new railway standards for the OCS.

Which TB/T part governs each fitting?
The TB/T 2075 series is organized in numbered parts by function, and the drawing numbers of the parts follow the same structure. Part 5, TB/T 2075.5-2024, covers terminal anchor clamps and encodes speed class, construction and body material into the type code. Part 6, TB/T 2075.6-2024, covers mid-point anchor assemblies; Part 8, TB/T 2075.8-2024, stitch wire assemblies; Part 11, TB/T 2075.11-2024, electrical connection assemblies; Part 12, TB/T 2075.12-2024, pulley compensation devices; Part 13, TB/T 2075.13-2024, ratchet compensation devices; Part 14, TB/T 2075.14-2024, spring compensation devices; and Part 22, TB/T 2075.22-2024, tunnel supports and positioning devices.
Reading the part number correctly is a selection skill in itself. A 13-1G ratchet compensation device, a 12-1G pulley compensation device and a 14A spring compensation device all decode back to their governing part, which in turn names the test evidence that must accompany them. The decoding rules are collected in our guide to cantilever part codes and designations and in the wider quick reference to OCS part codes.
How do TB/T and GB/T standards share the work?
The GB/T layer carries products that exist in both railway and general electrical service, and the TB/T layer adds railway duty on top. Contact wire is the clearest case: GB/T 12971.1-2023 covers copper and copper alloy contact wire generally, while TB/T 2809-2026 keeps only the railway alloys, having removed pure copper types from its scope, a signal of where alloy selection is now expected on anything faster or more heavily loaded than a regional line. Conductor practice shows the same pairing: LBGLJ aluminum conductor with an aluminum-clad steel core follows a layout equivalent to the JL/LB1A type of GB/T 1179-2017, while its railway strand duty is governed by the TB/T 3111 series.
Switchgear follows the pattern from the other side. The national standards GB/T 1985-2023 for high-voltage AC disconnectors and earthing switches and GB/T 1984-2024 for high-voltage AC circuit breakers, applied with the common requirements of GB/T 11022-2020, verify the generic device, and the traction power equipment technical conditions add the railway clauses. For supports, TB/T 2286-2020 provides the load class testing while GB/T 34199-2017 governs the hot-rolled sections and GB/T 25020.1-2025 consolidates the mast product requirements; the engineering context is in our guide to OCS mast types.
What does a compliant procurement file reference?
A complete file names three things explicitly: the governing TB/T designation with edition, the umbrella conditions, and the test evidence. For a section insulator that means TB/T 3036-2016 or TB/T 3252-2022 by system, read against TB/T 2073-2020, with the type test report delivered with the goods. For conductors it means the 2026 editions, TB/T 2809-2026 and the two TB/T 3111 parts, with the withdrawal date of the predecessor checked so that nothing in the file cites a dead standard. Selection tables for sectioning hardware are maintained in our section insulator model guide.
Monitoring closes the loop. The 6C system specified in TB/T 2076-2020 generates the inspection images and measurement streams that component condition is judged from, so component acceptance values and monitoring thresholds should trace to the same designations. How the TB/T layer relates to the European and international standards that export projects quote is mapped in our companion article on how IEC, EN and national standards divide the work, and the component landscape as a whole is surveyed in our complete guide to OCS components.
Frequently Asked Questions
What is OCS in railway?
OCS stands for overhead contact system: the assembly of contact wire, messenger wire, droppers, cantilevers, insulators, sectioning devices and supports that delivers traction power to the pantograph. In Chinese practice its components are governed by the TB/T standard families mapped in this article, from TB/T 2809-2026 for contact wire to TB/T 2075 for fittings.
What are the main components of overhead lines?
Conductors, which are contact wire and messenger wire with their strands; fittings, the clamps, compensation devices and cantilever parts of the TB/T 2075 series; insulators of the TB/T 3199 series; sectioning devices, namely section insulators to TB/T 3036-2016 and phase separation devices to TB/T 3037-2002; and supports type-tested to TB/T 2286-2020.
What is a catenary system?
A catenary system is the suspended assembly of messenger wire and contact wire hung from masts, with droppers between the two wires to set the contact wire height and stagger. The messenger wire carries the mechanical load and the contact wire carries the current to the pantograph. Its strands are governed by TB/T 3111.1-2026 and TB/T 3111.2-2026, and the contact wire alloy by TB/T 2809-2026.
What is traction power?
Traction power is the electrical energy supplied to trains for propulsion, delivered at 25 kV AC through the overhead contact system on main lines or at DC voltages such as 1500 V on urban rail. The fixed equipment that delivers it, from feeding sections to section insulators and disconnectors, is what the TB/T standards mapped here govern.
Working the map
Standards maps age quickly in the years after a revision round, so anchor every reference to a dated designation: TB/T 2809-2026, not TB/T 2809 alone; TB/T 3111.1-2026 and TB/T 3111.2-2026, not the merged 2017 edition. Where a component has both a TB/T and a GB/T designation, cite the one whose scope matches the duty, and keep the umbrella TB/T 2073-2020 in view for the general technical conditions.
For help locating the governing designation for a specific OCS component or checking which edition applies to an existing fleet, our engineering team maintains the cross-reference tables.