OCS mast types frame every later decision in overhead contact system (OCS) design, because the masts are where the wiring physically lands. The support structures fix the height, the stagger and the lateral position of the wiring; they absorb the wind, ice and tension loads the wiring generates; and they dominate the visual and cost profile of the electromechanical installation. Choose the mast family well and the rest of the cross-section design proceeds smoothly; choose it poorly and every subsequent stage inherits the compromise.
Three families carry most of the duty on electrified railways: lattice steel masts for heavy loads and long multi-track arrangements, H-section steel masts for standard single-track support, and guyed steel masts where anchor duties and material economy favour stayed construction. Prestressed concrete poles cover a parallel niche, and portable aluminium emergency masts handle failure recovery, but the three steel families between them frame most routine catenary pole selection.
This guide sets out what each family does well, how their designations encode capacity and height, and how the choice plays out in stations, on bridges and along mainline spans.
The loads a catenary mast must carry
A mast is a vertical cantilever beam in everything except geometry. Vertical load arrives from the weight of wires, fittings and, where fitted, head-span structures; horizontal load comes from wind pressure on wires and mast, from the transverse components of contact wire stagger and pull-off forces, and at anchor positions from the full working tension of the wires; ice loading adds mass and wind area simultaneously. The structural consequence is expressed as a bending moment at the base, which is why traction mast standards classify masts by moment capacity rather than by tonnage.
In the Chinese families used across mainline and metro electrification, the designation states the capacity directly: the numerals after the type letters give the standard bending moment class in kilonewton-metres, and the trailing figure gives the height in metres. Selection is therefore a matter of computing the design loads at the worst combination of wind, ice and temperature, adding anchor forces where relevant, and reading the required class from the standard series of TB/T 2286. Every mast in the families discussed below is type-tested against that class series and carries an earthing terminal for mast earthing and stray-current protection.
Lattice steel masts for long spans and heavy head-spans
Lattice construction converts steel into stiffness with remarkable economy. A four-legged or triangular laced column reaches high moment capacity with modest steel weight, tolerates large cantilever and bracket loads, and survives minor collision damage without loss of function. That combination suits the two heaviest duties in the OCS repertoire: long single spans where fewer structures interrupt clearways, and head-span arrangements where a pair of masts carries a truss across many parallel tracks.
The G-series lattice steel mast expresses the range numerically. Line masts run from G150/13 to G750/20, covering moment classes of 150 to 750 kN·m at heights of 13, 15 and 20 m, while the straight-leg Gq bridge masts span 80 to 200 kN·m at 9 to 12.5 m for deck-mounted duty. Q235B and Q345 grade steel is hot-dip galvanised with a zinc coating of at least 610 g/m² on members 5 mm and thicker, a protection level quoted to serve for 30 years or more. Erection is by direct burial or flange foundation with whole-mast lifting, and thickened galvanising is specified for coastal corridors. In station throats, the same masts work as head-span end supports, carrying the transverse beams that serve several tracks from two positions instead of one mast per track.
H-section steel masts for standard single-track support
The H-section steel mast is the workhorse of modern single-track support. A single hot-rolled column to GB/T 34199, in Q235B or Q355B, with a flanged base plate and anchor bolts, delivers high bending stiffness with economical steel consumption and a footprint small enough to suit constricted trackside space. Cantilevers bolt directly to the column face, insulation and registration hardware mount without adapters, and the whole mast hot-dip galvanising removes the painting cycle from the maintenance plan.
Designations such as GH240X to GH300X identify the family by column section height in millimetres, from 240 to 300 mm, with column lengths typically between 7.5 and 11 m chosen against the rail level to foundation level difference. Erection is deliberately simple: set the base on anchor bolts, level the mast with adjusting nuts, then torque the fasteners. The GH series serves as intermediate masts, anchor masts, transition masts and station yard masts on high-speed sections and conventional lines alike, and the current product standard GB/T 25020.1 consolidates the requirements that earlier covered H-section masts separately.

Guyed anchor masts at tension termination points
Anchor positions change the structural problem. A mast that terminates a tension length carries the full wire tension as a sustained horizontal force on top of wind and ice loads, and a free-standing column sized for that duty becomes heavy quickly. Guyed construction resolves the force instead of resisting it: stay wires, anchored to separate foundations, take the horizontal component, and the mast column carries mainly compression. The result uses less steel and smaller foundations, at the cost of stay footprints that must be kept clear of drainage, cable routes and siding operations.
The Gm350-250/15 guyed steel anchor mast follows the family naming: Gm marks a guyed anchor steel mast, the figures 350-250 denote its moment capacity in kilonewton-metres in the two load directions, and the final 15 is the height in metres. Built from Q235B or Q345 steel with the same minimum 610 g/m² galvanising and TB/T 2286 class testing as the free-standing families, it is intended for tension length joints and tensioning points where guys are part of the design. Installation remains direct burial or flange foundation with whole-mast erection, so a guyed anchor position differs from a standard position mainly in the stay layout and its foundations.

Individual masts or head-spans in stations
Stations force the mast plan into the open. One mast per track keeps loads small and future modification simple, but consumes a structure position for every track and multiplies foundations in the throat, where point machines and cable routes already compete for space. A head-span truss carried on two heavy lattice masts serves many tracks from two positions, shortens erection possessions and keeps the wiring geometry adjustable track by track; the price is heavier end structures, more complex insulator arrangements and a bigger single-point failure if a span is damaged. Most large throats mix the two: head-spans across the fan of platforms and sidings, individual masts on the plain route either side, and anchor groups wherever tension lengths end.
Choosing between OCS mast types
The selection logic compresses into a table, with capacities drawn from the standard class series each family is certified against.
| Family | Capacity range | Best suited to |
|---|---|---|
| G lattice steel | 150–750 kN·m, 13–20 m | Long spans, head-span ends, heavy loads |
| GH H-section steel | 240–300 mm sections, 7.5–11 m | Standard single-track support, station yards |
| Gm guyed steel | 350-250 kN·m, 15 m | Tension length joints and anchor points |
Fit the family to the duty first, then the specific class from the computed loads, and only then the details of foundation type, galvanising thickness and accessory fit-out. Where the load calculation, a mixed station layout or an unusual anchor arrangement raises questions, our engineering team can review the cross-section data and propose the mast schedule for the section.