FYFH-1.8BT Shuttle-Type Section Insulator (Type B, Inter-Phase) for 25kV OCS

TB/T 3036-2016 | Inter-phase sectioning | 27.5kV | Enhanced insulation

FYFH-1.8BT Shuttle-Type Section Insulator (Type B, Inter-Phase) for 25kV OCS

Specifications

ModelFYFH-1.8BT
StandardTB/T 3036-2016 Section Insulators for Electrified Railway OCS
Rated Voltage27.5kV rated (25kV AC 50Hz single-phase traction supply)
Design SpeedUp to 200 km/h (TB/T 3036-2016 upper limit)
Operating Temperature-40°C to +70°C
Altitude≤ 4,000 m
MaterialsHigh-strength aluminum alloy body; arc-resistant insulating elements (silicone rubber / porcelain); reinforced creepage
InstallationIn-line series suspension on the contact wire; both ends mechanically connected to the contact wire

The FYFH-1.8BT shuttle-type section insulator (Type B inter-phase variant) is designed and manufactured per TB/T 3036-2016 for inter-phase electrical sectioning on 25kV AC electrified railway overhead contact systems. Compared with the FYFH-1.8AT in-phase variant, the -BT version adds enhanced creepage distance and reinforced insulation geometry to handle inter-phase stress where adjacent OCS sections belong to different supply phases.

A high-strength aluminum alloy body carries the contact wire tensile load; arc-resistant insulating elements (silicone rubber or porcelain) with reinforced creepage provide inter-phase separation. Rated for 27.5kV systems, line speeds up to 200 km/h, -40°C to +70°C operating temperature and altitudes up to 4,000 m.

Typical applications include inter-phase sectioning points on mainline railways and at substation feeding boundaries. The unit is installed in-line with the contact wire as a horizontal series suspension with mechanical end connections.

Henan Chuangwit Railway Equipment provides datasheets, type test reports and project engineering support for the FYFH-1.8BT inter-phase variant.

Frequently Asked Questions

When is the FYFH-1.8BT used versus FYFH-1.8AT?

Use FYFH-1.8BT at inter-phase sectioning points where adjacent OCS sections belong to different supply phases; use FYFH-1.8AT for in-phase sectioning within a single supply zone.

What is the speed rating?

Up to 200 km/h per TB/T 3036-2016 upper limit, depending on sub-model and installation conditions.

Does it require special installation?

Installation is the same in-line series suspension as the -AT variant, but the inter-phase geometry requires verification of creepage distance per site-specific pollution severity.

Performance

Operating Conditions

Designed for continuous outdoor railway service from -40°C to +70°C at altitudes to 4,000 m, including humid and polluted atmospheres and inter-phase feeding boundaries.

Mechanical

Shuttle-type profile with controlled pantograph contact through the insulating zone; aluminum alloy body carries full contact wire tension; reinforced creepage geometry.

Electrical

Enhanced arc-resistant insulation with reinforced creepage provides inter-phase separation per TB/T 3036-2016 for 27.5kV systems, verified by type tests.

Applications

Inter-Phase Sectioning

Sectioning points where adjacent OCS sections belong to different supply phases.

Substation Feeding Boundaries

Boundaries between traction substation feeding zones.

Polluted & Coastal Areas

Reinforced creepage withstands high-pollution environments.

Cold Regions

Operation down to -40°C.