OCS SECTIONING & SWITCHING / 25 kV AC · 1.5 kV DC CRCC CERTIFIED / TB/T · GB · IEC

FYFH-1.8BT-E Enhanced Section Insulator (25kV)

Enhanced-insulation inter-phase section insulator per TB/T 3036-2016 for severe-service 25kV AC railway OCS, up to 200 km/h.

FYFH-1.8BT-E Enhanced Section Insulator (25kV)

This image shows a representative model of the series; the actual product may vary in appearance.

Specifications

ModelFYFH-1.8BT-E
Drawing No.CWLFD1.8BT-E-00
StandardTB/T 3036-2016 Section Insulators for Electrified Railway OCS
Rated Voltage27.5kV rated (25kV AC 50Hz single-phase traction supply)
Design SpeedUp to 200 km/h (designed to TB/T 3036-2016)
Operating Temperature-40°C to +70°C
Altitude≤ 4,000 m (designed for 2000-4000m high-altitude service)
MaterialsHigh-strength aluminum alloy body; arc-resistant insulating elements; reinforced creepage; enlarged air gap geometry
InstallationIn-line series suspension on the contact wire; both ends mechanically connected to the contact wire

The FYFH-1.8BT-E combines the inter-phase capability of the FYFH-1.8BT with the enhanced insulation geometry of the -E variant. It is designed and manufactured per TB/T 3036-2016 for inter-phase electrical sectioning of 25kV AC electrified railway overhead contact systems in severe-service environments.

The air insulation gap is enlarged to ≥430mm and creepage distance is reinforced for high-altitude lines (2000-4000m), coastal and salt-fog regions, and heavy-pollution industrial corridors — sites where both inter-phase stress and severe pollution must be managed simultaneously.

A high-strength aluminum alloy body carries the contact wire tensile load; arc-resistant insulating elements with reinforced creepage deliver inter-phase separation. Rated for 27.5kV systems, line speeds up to 200 km/h, -40°C to +70°C and altitudes up to 4,000 m.

Henan Chuangwit Railway Equipment provides datasheets, type test reports and project engineering support for the FYFH-1.8BT-E enhanced inter-phase variant.

Frequently Asked Questions

Which line scenarios is this model intended for?

Suitable for phase separation (out-of-phase) electrical sectioning on lines up to 200 km/h, especially severe service environments such as high altitude, heavy pollution, coastal areas and tunnels.

What does the enhanced insulation design comprise?

On the reinforced phase-separation structure, the air gap is enlarged to ≥430 mm and the creepage distance reinforced, forming dual insulation redundancy against phase voltage difference combined with heavy pollution.

What is the maximum permissible passing speed?

Maximum permissible passing speed ≤200 km/h, for phase-break sections on speed-raised and conventional trunk lines.

Which parameters matter when selecting for high-altitude phase-break sections?

Altitude ≤4000 m, applicable to phase-break sections at 2000-4000 m; operating temperature -40°C to +70°C; selection should be verified against severe service conditions.

Performance

Operating Conditions

Designed for severe-service outdoor railway environments combining inter-phase stress with high altitude, coastal/salt-fog, or heavy-pollution conditions.

Mechanical Performance

Aluminum alloy body carries full contact wire tension; reinforced insulation geometry supports enlarged air gap without increasing installation envelope excessively.

Electrical Performance

Enhanced arc-resistant insulation with air gap ≥430mm and extended creepage provides inter-phase separation per TB/T 3036-2016 for 27.5kV systems in severe-service inter-phase applications.

Applications

Inter-Phase + Severe Service

Inter-phase sectioning in high-altitude or heavy-pollution zones.

High-Altitude Boundaries

Substation feeding boundaries on plateau lines.

Coastal & Salt-Fog

Inter-phase sectioning on coastal corridors with salt pollution.

Cold Regions

Operation down to -40°C.