FQX/FQB Series Composite Long-Rod Insulator

FQX/FQB Series 25~27.5kV

FQX/FQB Series Composite Long-Rod Insulator

Specifications

ModelFQX/FQB
StandardGB/T 11030-2008, TB/T 3199 series “Insulators for electrified railway overhead contact system”
Rated Voltage25 kV overhead contact system
Operating Temperature-40℃~+70℃
Altitude<4000m
MaterialsHigh-strength porcelain insulating body or composite silicone, steel foot with zinc sleeve
InstallationSuspended on support cantilevers, positioning points and anchor points

Composite long-rod insulators use a silicone-rubber shed over a fibre-glass core rod, offering light weight, good anti-pollution performance and no need for periodic cleaning, to standard TB/T 3199.2-2018. Model designation: FQ — composite insulator; X — suspension type; B — long rod. Lightning impulse withstand voltage ≥270~310kV, dry power-frequency withstand voltage ≥160~190kV.

FQX/FQB series composite long-rod insulator, product photo

ModelRated voltageStructure height (mm)Minimum arc distance (mm)Minimum nominal creepage distance (mm)Rated load
FQX1-25/10025kV700±205001600Tension 100kN
FQX2-25/10025kV700±205001200Tension 100kN
FQB-25/4025kV700±205001200Bending 40kN
FQB-25/825kV850±204901200/150Bending 8kN
FQB-25/1225kV760±205201400Bending 12kN

Other common composite insulator models:long-rod suspension single insulation: FQX-25/100QT, FQX-25/100QH, FQX-25/120QT; long-rod suspension positioning: FQD-27.5/100HY, FQDJ-27.5/100HY; long-rod post type: FQZ-27.5/16-160. Model example: FQBS27.5/16-1600 denotes a cantilever insulator with double insulation, 27.5kV, 16kN bending load and 1600mm creepage distance.

Performance

Operating Conditions

Suitable for sections with different pollution levels; simultaneously withstands mechanical loads and electrical insulation stresses.

Mechanical Performance

Full range of 8–20 kN bending loads; every porcelain unit undergoes a mechanical load test. The composite version withstands impacts without breaking.

Electrical Performance

Dry and wet power-frequency withstand voltages, lightning impulse withstand voltage and creepage distance meet the requirements of TB/T 3199; the double-insulation type offers higher reliability.

Applications

Suspension on main-line support cantilevers

On main-line support cantilevers, composite rod insulators isolate the live components from the pole.

Coastal sections with severe pollution

In severely polluted coastal sections, composite rod insulators with a long creepage distance are used to prevent pollution flashover.

Insulation at anchor points

At anchor points, the composite rod insulator simultaneously withstands the tension and the insulation stress.

Extreme cold regions

In extreme cold sections, the units of composite rod insulators maintain stable frost and thaw resistance.