OCS SECTIONING & SWITCHING / 25 kV AC · 1.5 kV DC CRCC CERTIFIED / TB/T · GB · IEC

integral droppers (7-1A/7-1B, stamped/die-forged)

JL02(7A)-2010

integral droppers (7-1A/7-1B, stamped/die-forged)

Specifications

ModelJL02(7A)-2010; 7-1A/7-1B (stamped, die-forged)
StandardTB/T 2075.7-2024, OCS fittings for electrified railways — Part 7: Integral droppers, and JL02 drawing technical requirements
Operating Temperature-40℃~+70℃
Altitude<4000m
Materialscopper alloy stranded wire with precision crimp clamps
Installationvertical suspension installation between messenger wire and contact wire

Integral droppers (7-1A/7-1B) suspend the contact wire from the messenger wire in electrified railway OCS, in CuNi2Si by stamping.

Excellent mechanical and electrical performance: dropper clamp vertical failing load at least 3.9kN and dropper wire breaking load at least 5.67kN — safe, reliable and easy to maintain.

integral droppers (7-1A/7-1B, stamped/die-forged) product photo

Drawing No.JL02(7A)-2010
ApplicationFor suspending the contact wire from the messenger wire in electrified railway OCS.
MaterialCuNi2Si
Processstamped type
Performance1.maximum vertical straight working load of 1.3kN.
2.dropper clamp vertical straight failing loadat least 3.9kN.
3.dropper wire breaking loadat least 5.67kN.
4. and contact wire betweenSlip loadat least 1.0kN, and messenger wire betweenSlip loadat least 1.0kN, dropper clamp and crimp sleeve betweenSlip loadat least 3.9kN.

Certificate drawing Nos. 7-1A (stamped/die-forged) and 7-1B (stamped/die-forged). 7-1A is non-adjustable; 7-1B is adjustable (adjustment at least 200mm).

Performance

Operating Conditions

For all catenary types, transferring the contact wire suspension load and keeping contact height and stagger.

Mechanical Performance

Crimp grip at least 95% of the stranded wire rated breaking load; integral dropper length is precise with low strand spreading.

Electrical Performance

Conductive section meets ampacity requirements with low transition resistance at crimps.

Applications

High-speed catenary:

type A integral droppers (JL02(7A)-2010) keep the contact wire smooth on high-speed catenary.

Conventional railways:

type A integral droppers are fitted in volume on conventional lines.

Station areas:

type A integral droppers adapt to complex station layouts.

Urban rail OCS:

compact type A integral droppers suit urban rail OCS.

Need a quote or datasheet? Email Us WhatsApp Telegram