Pull-Off Registration vs Push-Up: Choosing Direction for Catenary Supports

Publisher · Henan Chuangwit Railway Equipment Co., Ltd.   Updated ·

Every registration point on an overhead contact system (OCS) does one of two things: it either draws the contact wire towards the supporting mast or it holds the wire away from the mast at its staggered position. The first arrangement is pull-off registration, the second is push-up, sometimes called push-off, registration. The choice is rarely free. It follows from the stagger direction at the support, the side of the track the structure occupies and the geometry of any curve, and getting it wrong overloads locators, bends positioning tubes and disturbs the very geometry the registration exists to protect.

Chinese hardware practice encodes the same distinction in its drawing conventions as positive, or normal, registration and negative registration, and the fitting families are shaped around it. Understanding which mode a support needs, and which hardware each mode demands, turns a confusing catalogue of locators, brackets and tubes into an ordered selection.

This article explains the two registration modes, how the line geometry decides between them, what each mode does to the forces in the positioning hardware, and how direction changes and station layouts are handled.

The two registration modes defined

Pull-off registration places the locator anchor on the mast side of the contact wire and pulls the wire towards the structure. The lateral resultant of the contact wire tension at that support acts away from the mast, and the locator restrains it, working along its length in tension. Because a tension member can be a rope, pull-off points are where flexible and rope-based registration devices are practical.

Push-up registration is the mirror image. The wire tends to move towards the mast, and the positioning device must hold it out at the design stagger, exerting a force on the wire directed away from the structure. The anchor then sits beyond the wire or at the end of a rigid arrangement, and the locator works as a strut. A rope cannot serve here; the device must be a rigid tube capable of carrying compression and the transverse loads of a passing pantograph.

How stagger and curve geometry decide the direction

On straight track the stagger alternates side to side, commonly 200 to 300 mm each way on mainline AC lines, so the lateral resultant at each support flips direction from one support to the next. Adjacent registrations therefore usually alternate between pull-off and push-up, and the pole line sits to one side, the mapping of stagger sign to mode is fixed for every support of the section. The cross-section plan states the stagger at each structure, and the registration direction follows without further argument.

Curves superimpose a steady lateral component. Wire tension acting around a curve produces a continuous force towards the inside of the curve, so every registration point on the curve carries a base load in one direction, modified by the local stagger. Designers prefer to arrange curve registration so that locators are loaded towards their anchors, in the pull-off sense, wherever the structure spacing and track centres allow, and where push-up duty is unavoidable the positioning tube class and its bracing are upgraded accordingly. Wind exposure adds a variable component, which is why exposed curve sections are checked for the worst combination of stagger, wind and ice rather than the nominal case alone.

Forces in locators, tubes and registration brackets

Whichever mode applies, the load path is the same: contact wire, registration clamp, locator, registration bracket, positioning tube, cantilever. What changes is the sign and distribution of the forces. The 3-1 Limit Locator (3-1A / 3-1B) illustrates the duties: its stop face works against the bracket so that dynamic uplift of the contact wire is limited to the designed value while lateral stagger is held, with the 3-1A straight-tube round section serving lines up to 250 km/h and the 3-1B bent tube with rectangular section serving 250 to 350 km/h lines. A 6082 aluminium alloy body keeps the mass low at the point where dynamics concentrate.

The bracket that receives the locator is the 3-2 Registration Bracket (Types A / B / D), a rotating bracket sleeved on the positioning tube that carries the locator through its hook. The rotating fit lets the registration follow the dynamic movement of the contact wire without sticking, and the clamp connection with hole adjustment allows the bracket to sit anywhere along the tube and be re-tightened after adjustment. Type A, the straight form, serves normal registration points; Type B, a bent form, provides offset where the geometry of the point needs it; and Type D is the head-span version for registration ropes of 9 to 11 mm diameter. Between them the three types cover positive registration, negative registration and head-span installations, so the mode chosen at a support also selects the bracket variant.

3-2 registration bracket sleeved on a positioning tube carrying a locator hook at a catenary support

Flexible locators for pull-off registration

Pull-off points admit a lighter solution than a rigid tube. The 4-4 Flexible Locator is a bent tube whose head grips the contact wire through a registration clamp while its tail is held by a tensioned rope anchored to a registration eye on the cantilever. Adjustment is made by altering the rope tension and the tube position, and because the tail is a rope in tension, the arrangement belongs mainly at negative-registration points, where the contact wire must be pulled towards the mast side. Station yards and layouts that need soft registration use it to reduce the rigid mass hanging at the wire while keeping the lateral position steady.

4-4 flexible locator with bent tube head and tensioned rope tail at a negative registration point

Direction changes, overlaps and anchors

Because stagger alternates, the registration direction changes at every support on straight track, which the hardware absorbs without ceremony. The sensitive places are where the pattern is interrupted: mid-section direction reversals of the pole line, overlaps between tension lengths, and anchor points. In an overlap two contact wires run side by side, and each dead branch must be held clear so the pantograph never catches the outgoing wire, a duty that falls to anchor clips on the anchor-mast support tube. At an anchor itself the wire tension stops at the structure, so the registration hardware on the adjacent spans sees an asymmetric pull, and the tube and locator selected there must be checked against the one-sided case rather than the alternating one.

Where the resultant force at a point passes close to zero, for example near a direction change on a gently curving track, a locator can go slack and chatter. Good practice is to bias the stagger slightly so every registration point keeps a definite load direction, keeping the hardware positively engaged under all wind and temperature states.

Conventions inside stations

Stations concentrate the special cases. Head-span structures carry several tracks from shared columns, and their registration is done with ropes rather than tubes, which is why the head-span bracket type for 9 to 11 mm registration rope exists in the same family as the trackside types. Multiple tracks mean the same column registers wires on both sides, so pull-off and push-up points coexist on one structure, and low station speeds make soft registration acceptable on most points. Projects that fix one convention per station, which mode each track uses and which bracket type serves it, consistently report fewer erection errors and simpler spares holdings than those that let each support be solved afresh.

AspectPull-offPush-up
Force on wireTowards the mastAway from the mast
Locator loadingTensionCompression and bending
Tube arrangementShort tube or ropeRigid tube, braced reach
Suitable devicesFlexible and rope locatorsRigid bent-tube locators
Typical spotsNegative registration pointsNormal registration points

Registration direction is decided by geometry, not preference, but the hardware that serves each mode is a genuine choice. For help fixing the mode, bracket type and locator family for a specific section, contact our engineering team.