FYFH-0.6T-DC Rigid Metro Section Insulator for 1500V DC Rigid Suspension OCS

TB/T 3252-2022 | 1500V DC metro rigid suspension | Compact | ≤120km/h

FYFH-0.6T-DC Rigid Metro Section Insulator for 1500V DC Rigid Suspension OCS

Specifications

ModelFYFH-0.6T-DC
StandardTB/T 3252-2022 Rigid Suspension Catenary Busbar and Components for Electrified Railway
Rated VoltageDC 1500V (rigid suspension)
Design SpeedUp to 120 km/h (metro lines)
Operating Temperature-40°C to +70°C
Altitude≤ 4,000 m
MaterialsHigh-strength insulating elements; aluminum alloy runners; stainless steel fasteners
InstallationMounted at rigid suspension points within the conductor rail run

The FYFH-0.6T-DC rigid metro section insulator is designed and manufactured per TB/T 3252-2022 (Rigid Suspension Catenary Busbar and Components for Electrified Railway) for in-phase electrical sectioning of 1500V DC metro and urban rail rigid suspension overhead contact systems. It replaces the legacy DC1500V designation in the Henan Chuangwit Railway Equipment catalogue.

The compact structure fits the limited envelope of tunnel-mounted rigid conductor rail installations while maintaining the required insulation performance. High-strength insulating elements, aluminum alloy runners and stainless steel fasteners give a durable assembly rated for metro speeds up to 120 km/h, operating from -40°C to +70°C at altitudes up to 4,000 m.

The unit mounts at rigid suspension points as part of the conductor rail run. Drawing number CWLFD0.6T-DC-00.

Henan Chuangwit Railway Equipment Co., Ltd. provides drawings, type test documentation and project support for FYFH-0.6T-DC rigid OCS sectioning applications.

Frequently Asked Questions

What is a rigid suspension OCS?

It uses an overhead conductor rail instead of a flexible contact wire, common in metro tunnels for its compact gauge and low maintenance. This insulator sections such conductor rail runs.

Which standard applies?

TB/T 3252-2022 (Rigid Suspension Catenary Busbar and Components for Electrified Railway).

How compact is the unit?

It is designed to fit within standard rigid OCS tunnel envelopes; detailed dimensions are in the datasheet available on request.

Performance

Operating Conditions

Metro tunnel service from -40°C to +70°C, altitudes to 4,000 m, including humid underground atmospheres.

Mechanical

Compact rigid assembly integrates into the conductor rail run; smooth pantograph transition up to 120 km/h.

Electrical

High-strength insulating elements deliver reliable section separation on 1500V DC rigid OCS per TB/T 3252-2022.

Applications

Rigid OCS Tunnels

Sectioning conductor rail runs in metro tunnels.

Underground Stations

Compact sectioning in restricted station envelopes.

Humid Tunnels

Materials suited to humid underground service.

Cold Regions

Operation down to -40°C.

Need a quote or datasheet? Email Us WhatsApp