1.5kV 3150A DC Disconnect Switch for Metro Traction Power

IEC 61992-3 aligned | Outdoor type | Reliable breaking

1.5kV 3150A DC Disconnect Switch for Metro Traction Power

Specifications

ModelZGW1-1.5/3150
StandardIEC 61992-3 (DC disconnectors for railway fixed installations) and metro DC traction power supply technical conditions
Rated VoltageDC 1500V (3150A rated current)
Design SpeedN/A (fixed installation equipment)
Operating Temperature-40°C to +70°C
Altitude≤ 4,000 m
MaterialsDedicated DC arc-extinguishing contact system; hot-dip galvanized steel structure; high-strength insulation
InstallationMounted in traction substations or trackside boxes; motorized or manual operation

The ZGW1-1.5/3150 is a 1.5kV DC, 3150A outdoor disconnect switch designed for electrical isolation in metro and urban rail DC traction power supply systems. It isolates sections of the 1500V DC overhead contact system for maintenance and operational switching.

The switch is designed with reference to IEC 61992-3 (Railway applications — Fixed installations — DC switchgear — Part 3: Disconnectors, switch-disconnectors and earthing switches) and relevant metro DC traction power supply technical specifications. A dedicated DC arc-extinguishing contact system ensures reliable breaking under DC load conditions; the hot-dip galvanized steel structure and high-strength insulation suit long-term outdoor service from -40°C to +70°C at altitudes up to 4,000 m.

Installation options include mounting inside traction substations or in trackside boxes, with motorized or manual operating mechanisms available to match the automation level of the line.

Henan Chuangwei Railway Equipment Co., Ltd. supplies the ZGW1 series with type test documentation and engineering support for metro projects worldwide.

Frequently Asked Questions

What is a DC disconnect switch used for in metro systems?

It isolates sections of the 1500V DC traction power network — for example at substations or between line sections — so maintenance can be performed safely without de-energizing the whole line.

Which standard does the ZGW1-1.5/3150 follow?

It is designed with reference to IEC 61992-3 for DC disconnectors, plus metro DC traction power supply technical conditions.

Motorized or manual operation?

Both are available. Motorized mechanisms support remote control and automation retrofits; manual mechanisms suit simpler installations.

Performance

Operating Conditions

Long-term outdoor service in metro DC traction power environments from -40°C to +70°C, altitudes to 4,000 m.

Mechanical

Hot-dip galvanized steel frame with high-strength insulators; robust mechanism for frequent switching duty.

Electrical

Dedicated DC arc-extinguishing contacts provide reliable breaking at 1500V DC / 3150A, designed per IEC 61992-3.

Applications

Metro Substations

DC isolation inside traction substations.

Trackside Boxes

Section isolation along the line in compact enclosures.

Outdoor Service

Galvanized structure for open-air installations.

Cold Regions

Operation down to -40°C.

Need a quote or datasheet? Email Us WhatsApp