GW4-27.5/1250D Outdoor HV Disconnect Switch with Earthing Blade (27.5kV)

Integrated earthing blade | Reliable interlocking | High safety

GW4-27.5/1250D Outdoor HV Disconnect Switch with Earthing Blade (27.5kV)

Specifications

ModelGW4-27.5/1250D
StandardGB 1985-2014 HV AC disconnectors and earthing switches; TB/T railway industry standards
Rated Voltage27.5kV / 10kV / 15kV (per model)
Design SpeedN/A (fixed installation equipment)
Operating Temperature-40°C to +70°C
Altitude≤ 4,000 m
MaterialsHot-dip galvanized steel frame; copper alloy contacts; high-strength post insulators
InstallationPole-side or independent foundation mounting; manual / motorized / hand-crank operating mechanisms

The GW4-27.5/1250D is an outdoor high-voltage disconnect switch rated 27.5kV with an integrated earthing blade. It is designed for maintenance earthing scenarios on electrified railway catenary and substations: after isolating the circuit, the earthing blade grounds the dead side so crews can work safely.

Mechanical interlocking between the main blade and the earthing blade prevents incorrect operating sequences, raising on-site safety. The switch is built per GB 1985-2014 and TB/T railway industry standards with a hot-dip galvanized steel frame, copper alloy contacts and high-strength post insulators, rated for -40°C to +70°C and altitudes up to 4,000 m.

Installation is pole-side or on independent foundations, with manual, motorized or hand-crank operating mechanisms available.

Contact Henan Chuangwei Railway Equipment Co., Ltd. for datasheets and project support.

Frequently Asked Questions

What is the earthing blade for?

After the main blade isolates the circuit, the earthing blade grounds the de-energized side, protecting maintenance crews against induced voltage and accidental re-energization.

How is wrong operation prevented?

A mechanical interlock between main and earthing blades enforces the correct operating sequence — the earthing blade cannot close while the main blade is closed, and vice versa.

Which standard applies?

GB 1985-2014 (HV AC disconnectors and earthing switches) plus TB/T railway industry standards.

Performance

Operating Conditions

Outdoor traction power service from -40°C to +70°C, altitudes to 4,000 m, including polluted and humid environments.

Mechanical

GW4 platform with integrated earthing blade and mechanical interlock enforcing safe operating sequences.

Electrical

27.5kV isolation with maintenance earthing capability per GB 1985-2014 for railway catenary and substations.

Applications

Maintenance Earthing

Ground the dead side before crew access.

Catenary Isolation

Section isolation with integrated earthing.

Outdoor Service

Galvanized structure for open-air duty.

Cold Regions

Operation down to -40°C.

Need a quote or datasheet? Email Us WhatsApp