OCS SECTIONING & SWITCHING / 25 kV AC · 1.5 kV DC CRCC CERTIFIED / TB/T · GB · IEC

JL05(11CT)-2010 CT-type messenger wire connection clamp

JL05(11CT)-2010

JL05(11CT)-2010 CT-type messenger wire connection clamp

Specifications

ModelJL05(11CT)-2010
StandardTB/T 2075Series standards
Operating Temperature-40℃~+70℃
Altitude<4000m
Materialscopper alloy clamps with soft copper connection cables
Installationjoints between messenger wire and contact wire, at tension length joints and turnouts

The CT-type messenger wire connection clamp (drawing No. JL05(11CT)-2010) serves joints between connection cables and messenger wires in electrified OCS systems, in T2 copper by die forging.

Excellent mechanical and electrical performance: slip load between the clamp and the messenger wire or connection cable at least 4.0kN, ampacity not lower than the rated ampacity of the joined wire — safe and reliable in service.

JL05(11CT)-2010 CT-type messenger wire connection clamp product photo

Drawing No.JL05(11CT)-2010
ApplicationThis fitting suits joints between connection cables and messenger wires in electrified OCS systems.
MaterialT2 (large block)
Processdie forging
Mechanical performance1.messenger wireconnection clamp and messenger wire and connection cable betweenSlip load all at least 4.0kN.
2.messenger wireconnection clampbolt tightening torque of 44N·m~56N·m.
Electrical performance1.connection clampampacity not lower than that of the joinedwirerated ampacity.
2.connection clamp and wireconnection pointtemperature rise not higher than that of the joinedwire temperature rise.
3.over loadelectro-thermal cyclingtested after messenger wireconnection clamp and conductor joint pointjoint contact resistance at both endpoints not higher than etc.length of joined wire resistance.

Performance

Operating Conditions

For all conductive nodes of the OCS, ensuring smooth traction current return.

Mechanical Performance

The clamp grips reliably without damaging the wire; the connection cable is soft and bend-tolerant.

Electrical Performance

Low transition resistance; ampacity satisfies traction current requirements without overheating in long-term service.

Applications

Tension length joints:

CT-type clamps (JL05(11CT)-2010) ensure electrical continuity across tension lengths.

Turnout areas:

CT-type clamps provide equipotential bonding between OCS legs at turnouts.

Mainline suspension points:

CT-type clamps split current between messenger wire and contact wire on mainlines.

Feeder nodes:

CT-type clamps carry high current at feeder introduction points.