OCS SECTIONING & SWITCHING / 25 kV AC · 1.5 kV DC CRCC CERTIFIED / TB/T · GB · IEC

JQJL04(11JB)-2010 JB-type contact wire connection clamp

JQJL04(11JB)-2010

JQJL04(11JB)-2010 JB-type contact wire connection clamp

Specifications

ModelJQJL04(11JB)-2010
StandardTB/T 2075Series standards
Operating Temperature-40℃~+70℃
Altitude<4000m
Materialscopper alloy clamps with soft copper connection cables
Installationjoints between messenger wire and contact wire, at tension length joints and turnouts

The JB-type contact wire connection clamp (drawing No. JQJL04(11JB)-2010) serves joints between connection cables and contact wires in electrified OCS systems, in CuNi2Si/T2 by die forging.

Excellent mechanical and electrical performance: slip load between the clamp and the contact wire at least 4.0kN, ampacity not lower than the rated ampacity of the joined wire — safe and reliable in service.

JQJL04(11JB)-2010 JB-type contact wire connection clamp product photo

Drawing No.JQJL04(11JB)-2010
ApplicationThis fitting suits joints between connection cables and contact wires in electrified OCS systems.
MaterialCuNi2Si/T2
Processdie forging
Mechanical performance1.connection clamp and contact wire betweenSlip loadat least 4.0kN.
2.connection clamp and connection cablegrip load after crimpingat least 4.0kN.
3.connection clampbolt tightening torque of 44N·m~56N·m.
Electrical performance1.clamp ampacity shouldat least joined wirerated ampacity.
2. clamp and wireconnection pointtemperature rise not higher than that of the joinedwire temperature rise.
3.over loadelectro-thermal cyclingtested clamp after and conductor joint pointjoint contact resistance at both endpoints not higher than etc.length of joined wire resistance.

Performance

Operating Conditions

For all conductive nodes of the OCS, ensuring smooth traction current return.

Mechanical Performance

The clamp grips reliably without damaging the wire; the connection cable is soft and bend-tolerant.

Electrical Performance

Low transition resistance; ampacity satisfies traction current requirements without overheating in long-term service.

Applications

Tension length joints:

JB-type clamps (JQJL04(11JB)-2010) ensure electrical continuity across tension lengths.

Turnout areas:

JB-type clamps provide equipotential bonding between OCS legs at turnouts.

Mainline suspension points:

JB-type clamps split current between messenger wire and contact wire on mainlines.

Feeder nodes:

JB-type clamps carry high current at feeder introduction points.

Need a quote or datasheet? Email Us WhatsApp Telegram