OCS SECTIONING & SWITCHING / 25 kV AC · 1.5 kV DC CRCC CERTIFIED / TB/T · GB · IEC

HThe cross-arm prestressed concrete pole series

TB/T 2286 C50prestressed concrete

HThe cross-arm prestressed concrete pole series

Specifications

ModelH series
StandardGB/T 25020, TB/T 2286 (steel masts for electrified railway OCS) Series standards
Operating Temperature-40℃~+70℃
Altitude<4000m
MaterialsQ235B/Q355Bsteel with hot-dip galvanizing, prestressed concrete, aluminium alloy (emergency repair)
Installationdirect burial/flange foundation installation, whole-mast erection

cross-arm (H type)prestressed concrete poles cost less and insulate well, and are very common on conventional-speed railways.Designed and produced to the TB/T 2286 series industry standard, with concrete strength class at least C50.In the model H denotes the cross-arm concrete pole; the numbers give mast capacity (kN·m), height above ground and embedment (m); some poles use cup foundations (denominator 1.5 in the size) or flange foundations.

HThe cross-arm prestressed concrete pole series product photo

Common modelsMast capacity(kN·m)Height above ground(m)Embedment depth(m)Notes
H60/8.7+3.0608.73.0one of the most basic common models
H78/8.7+3.0788.73.0slightly larger capacity
H170-250/12+3.5170123.5large-capacity, tall mast
StandardTB/T 2286 series
Structure typecross-arm (H type)
Concrete strengthat least C50
Foundation typecup foundation (denominator 1.5) or flange foundation
Scope of applicationsupports of conventional-speed railway OCS

Performance

Operating Conditions

for sections, station OCS support structures, bearing suspension load, wind load and ice load.

Mechanical Performance

Standard test bending moments meet the TB/T 2286 class series; hot-dip galvanizing lasts at least 30 years and concrete pole crack resistance is type-tested.

Electrical Performance

with earthing terminal, meeting mast earthing and stray-current protection requirements.

Applications

cross-arm prestressed concrete poles on mainline sections H series are arranged by span and load on mainline sections.

Station throat areas:

cross-arm prestressed concretemast H series work with head-span beams in multi-track station areas.

Emergency repair:

cross-arm prestressed concretemast H series restore power supply quickly after storm-pole failures.

Corrosive environments:

cross-arm prestressed concretemast H series use thickened hot-dip galvanizing in coastal corrosive environments.

Need a quote or datasheet? Email Us WhatsApp Telegram